How to use the ultrasonic slimming machine to weight loss?
2023-12-09 10:21
About the ultrasonic slimming machine, when received the cavitation and radiofrequency machine, first time follow the
instruction to fit and operate the machine. The slimming beauty machine have 5 handle, 40Khz Ultrasonic handle,
Vacuum Bipolar RF handle, Tripolar facial handle, Sextupole body RF handle, Quadrupole RF handle.
Panel:Press "RF CHANNEL" in the display screen to select vacuum bipolar RF output, select the suitable intensity
(adjust according to the customer's acceptable level, 3-6 is ok.), and at last press“work”key. The starts to work.
Beautifying: Use the probe to massage the specific part of skin circularly after applying the sliming cream for
about 30 to 40 minutes. ultrasonic fat burner could quicken the blood circulation in the part of skin treated and
has the effect of decomposing fat, etc.
Body cavitation machine Matters needing attention:
1. Body cavitation machine Apply sliming cream or cooling gel to the part of skin to be treated before the treatment.
2. Keep close contact between the probe and the skin.
3. Adjust the intensity from low level to high level.
4. Please do not irradiate eyeball directly with colored light.
5 Operate with the bipolar vacuum head for 15-20 minutes with mainly the spiral movement on body
Press "TIME SET" to adjust the time, clicking "+" to increase the RF intensity or "-" to decrease RF intensity, press
"work" to start the operation of negative pressure vacuum RF head. Apply gel to the negative pressure vacuum
RF head, point it to the position for losing weight and operate in pulling technique (drag fat at the position for
losing weight to the position where it is closer to the lymph gland) for about 20 minutes.
Notes:
1. Spread gel or essence on the treated positions for hairdressing evenly
2. In use, start with low-energy. We suggest to try for the proper energy level on the back of clients' hands before
using on body of them
3. Do not use essential oil as the medium
4. In operation, start pulling only after negative pressure head is attached to skin.
5. Turn off the instrument probe when it is not in use.
6. Operate with the tripolar RF head for 15-20 minutes with mainly the spiral movement on body.
Press "TIME SET" to adjust the time,clicking "-" to decrease the strength or click "+" to increase it. Press "PAUSE"
to start the strong sound wave explosion fat head
Mode a.b.c.d means that:
"A" is continuous working for 3 sec and discontinuous for 3 sec.
"B" is continuous working for 2 sec and discontinuous for 2sec.
"C" is continuous working for 1 sec and discontinuous for 1 sec.
"D" is continuous working for 0.5 sec and discontinuous for 0.5sec.
Operate with the 40KHz cavitation head for 15-20 minutes with mainly the spiral movement on body.
Get the latest price? We'll respond as soon as possible(within 12 hours)